The objective of the test was to determine the maximum amount of energy wich the Softstop-system can absorb during an impact at a height of 50 cm, without failure i.e. breaking, bending and/or cracking of the system.

Results:

  • Type 1: 1621 Joule
  • Type 2: 2667 Joule
  • Type 3: 12934 Joule

The table below gives the “holdpower” of just 1 Softstopelement with a frontal impact.
A rigid connection of 2 Softstop-elements gives the double “holdpower” etc. Ask our advice.

Mass (kg) Speed km/h
SOFTSTOP® type 1 (ductile cast iron)

tube diameter ø76,1×5mm
1621 Joules
Calculate Energy Absorption

500 9,2
800 7,3
1200 5,9
1500 5,3
SOFTSTOP® type 2 (ductile cast iron)

tube diameter ø101,6×6,3mm
2667 Joules
Calculate Energy Absorption

500 11,7
800 9,2
1200 7,6
1500 6,8
2000 5,9
2500 5,2
SOFTSTOP® type 3 (ductile cast iron)

tube diameter ø177,8×8mm
12934 Joules
Calculate Energy Absorption

500 26
800 20,5
1200 16,7
1500 14,9
2000 13,0
2500 11,6
3000 10,6
3500 9,8
4000 9,2
5000 8,2
6000 7,5
8000 6,5
10000 5,8