The objective of the test was to determine the maximum amount of energy wich the Softstop-system can absorb during an impact at a height of 50 cm, without failure i.e. breaking, bending and/or cracking of the system.
Results:
- Type 1: 1621 Joule
- Type 2: 2667 Joule
- Type 3: 12934 Joule
The table below gives the “holdpower” of just 1 Softstopelement with a frontal impact.
A rigid connection of 2 Softstop-elements gives the double “holdpower” etc. Ask our advice.
| Mass (kg) | Speed km/h | |
| SOFTSTOP® type 1 (ductile cast iron)
tube diameter ø76,1×5mm |
500 | 9,2 |
| 800 | 7,3 | |
| 1200 | 5,9 | |
| 1500 | 5,3 | |
| SOFTSTOP® type 2 (ductile cast iron)
tube diameter ø101,6×6,3mm |
500 | 11,7 |
| 800 | 9,2 | |
| 1200 | 7,6 | |
| 1500 | 6,8 | |
| 2000 | 5,9 | |
| 2500 | 5,2 | |
| SOFTSTOP® type 3 (ductile cast iron)
tube diameter ø177,8×8mm |
500 | 26 |
| 800 | 20,5 | |
| 1200 | 16,7 | |
| 1500 | 14,9 | |
| 2000 | 13,0 | |
| 2500 | 11,6 | |
| 3000 | 10,6 | |
| 3500 | 9,8 | |
| 4000 | 9,2 | |
| 5000 | 8,2 | |
| 6000 | 7,5 | |
| 8000 | 6,5 | |
| 10000 | 5,8 | |
Nederlands